M500

Web User Interface

System→ Alarm → Alarm → Alarm type

Phone User Interface

N/A

Initial Firmware Version

1.14.4

Text Configuration

alarm.x.type = VALIDVALUE

Description

Defines the method that is used to trigger the M56 alarm for the specified alarm profile.  

ValueMethod
alarm button

Press and hold the alarm key on the top of the M56 handset for 1.5 seconds + alarm.x.trigger_delay time

running
  • Swing or shake the M56 handset with frequency > 1.5 Hz in any direction
  • Continuous action >  alarm.x.trigger_delay + 3 seconds
no movement
  • M56 handset in a steady position (any angle)
  • Continuous no movement time >  alarm.x.trigger_delay time (e.g. if the user is sleeping or forgot to bring the handset)
man down
  • M56 handset lay down in horizontal position: 0-15 degrees
  • Continuous no movement time >  alarm.x.trigger_delay + 5 seconds (Note: If M56 handset is in horizontal position and steady, it will trigger No movement alarm first. If pre-alarm is disregarded then it will trigger Man down alarm.)

OR

  • Continuous movement (in horizontal direction) time >  alarm.x.trigger_delay + 5 seconds (This case is assumed an injured person laying down but can move slowly.)

where x = Alarm profile number (1-8)

Valid Values

alarm button, running, no movement, man down, disabled

Default Value

disabled